Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
J. res. dent ; 3(1): 583-591, jan.-feb2015.
Article in English | LILACS-Express | LILACS | ID: biblio-1363315

ABSTRACT

AIM: To clinically evaluate biofilm growth on 4 liners in complete denture base surfaces of 20 geriatric patients. MATERIAL AND METHODS: Patients received new complete maxillary dentures prepared with 4 chambers (10x10x2 mm) in the tissue surface of acrylic denture base. Each of the 4 chambers was randomly filled with the following denture liners: Eversoft (M1); Kooliner (M2); GC Reline Extra Soft (M3); Elite Soft Relining (M4). Patients were randomly separated into 2 treatment groups: T1- sanitization with soft brush and dentifrice; T2- similar to T1 with daily immersion in cleansing chemical solution (Ortoform). Patients had 8 follow-up sessions over a 3-month period. The internal denture surface was stained with a dental plaque dye at each of the follow-up visits. Standardized photographs were taken, and biofilm growth was scored. Data were tabulated and submitted to Analysis of Variance. Means were compared by Tukey (p<0.05) and T tests. RESULTS: Kooliner (M2) means were significantly different from the others for both groups T1 and T2. Treatment 1 promoted higher biofilm growth scores than treatment 2. The highest score after treatment 1 was Kooliner (M2) and the lowest was Elite Soft Relining (M4). As for treatment 2, Eversoft (M1) was statistically different from Elite Soft Relining (M4). Again, Kooliner (M2) presented the highest score and Elite Soft Relining (M4) the lowest. Kooliner (M2) was statistically different from both GC Reline Extra Soft (M3) and Elite Soft Relining (M4). CONCLUSION: Of the materials and treatments studied, the best clinical selection for lower biofilm growth scores would be Elite Soft Relining (M4) with treatment 2.

2.
Braz. dent. j ; 23(3): 218-222, 2012. tab
Article in English | LILACS | ID: lil-641590

ABSTRACT

The purpose of this study was to evaluate the effects of adhesive primer applications on the bond strength of resin cements to cast titanium. Four adhesive primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - and their respective resin cements - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - were tested. Cast plates were prepared from titanium ingots (n=6 specimens/cement) and had their surfaces airborne-particle abraded with Al2O3 (50 μ m). Three resin cement cylinders were built on each bonded titanium surface, using a cylindrical translucent tubing mold and were subjected to micro-shear testing. Data were analyzed statistically by two-way ANOVA and Tukey's post-hoc test (α=0.05). The application of Metal Primer II and Ceramic Primer resulted in significant higher bond strength for Link Max and RelyX Unicem resin cements, respectively, than nonuse of adhesive primers. Panavia F 2.0 and RelyX ARC yielded high bond strength means with or without adhesive primers. The use of adhesive primers might increase the bond strength to cast titanium depending on the resin cement used.


O objetivo deste estudo foi avaliar o efeito da aplicação de primers na resistência de união de cimentos resinosos ao titânio. Quatro primers - Metaltite, Metal Primer II, Alloy Primer and Ceramic Primer - e seus respectivos cimentos resinosos - Bistite II DC, Link Max, Panavia F 2.0, RelyX Unicem and RelyX ARC - foram testados. Placas de titânio foram preparadas a partir da fundição de lingotes (n=6 espécimes/cimento) e as superfícies dessas placas foram jateadas com partículas de Al2O3 (50 μ m). Três cilindros de cimento resinoso foram construídos em cada placa de titânio, utilizando moldes transparentes com formato de cilindro e foram submetidos ao teste de microcisalhamento. Os dados foram analisados pela ANOVA (dois fatores) e teste de Tukey (α=0,05). A aplicação do Metal Primer II e do Ceramic Primer resultou no aumento significativo da resistência de união para os cimentos resinosos Link Max e RelyX Unicem, respectivamente. Os cimentos Panavia F 2.0 e o RelyX ARC mostraram altos valores de resistência de união com ou sem o uso dos primers. A aplicação dos primers pode aumentar a resistência de união dos cimentos resinosos ao titânio, dependendo do tipo de cimento resinoso utilizado.


Subject(s)
Dental Alloys/chemistry , Dental Bonding/methods , Methacrylates/chemistry , Resin Cements/chemistry , Titanium/chemistry , Analysis of Variance , Dental Stress Analysis , Shear Strength , Tensile Strength
3.
J. Health Sci. Inst ; 29(4)oct.-dec. 2011. ilus
Article in Portuguese | LILACS | ID: lil-641417

ABSTRACT

Reabilitações protéticas sobre implantes ainda é um desafio para Odontologia. Existem situações em que os implantes são colocados em locais não compatíveis com o posicionamento dos dentes no arco, sendo necessário utilizar compensações protéticas capazes de corrigir essa dificuldade. Este trabalho tem como objetivo, relatar um caso clínico que apresenta uma opção protética para compensar o mau posicionamento dos implantes, pelo uso de uma mesoestrutura metálica. O paciente apresentava uma deformação óssea na região anterior de maxila onde foram instalados quatro implantes, posicionados de tal forma que os acessos aos parafusos protéticos ocorriam em áreas estética e biomecanicamente desfavoráveis. Portanto, foi planejado a confecção de uma mesoestrutura metálica, alterando a região de acesso aos parafusos protéticos, o que proporcionou ótimo resultado estético e satisfação do paciente.


Prosthetic rehabilitation on implants is still a challenge for Dentistry. There are situations where the implants are placed in locations that are not compatible with the positioning of the teeth in the arch, prosthetic compensation is necessary to be able to fix this problem. This study aims, report a clinical case that presents a prosthetic option to compensate the poor positioning of implants, by using a metallic mesostructure.The patient had a bone deformation in the anterior maxilla where four implants were installed, positioned so that access to prosthetic screws occurred in areas aesthetics and biomechanically unfavorable. So it was planned the construction of a metallic mesostructure, changing the area of access to prosthetic screws, which provided excellent aesthetic results and patient satisfaction.

4.
RFO UPF ; 16(1)jan.-abr. 2011.
Article in Portuguese | LILACS | ID: lil-593678

ABSTRACT

Objetivo: Este estudo teve por objetivo avaliar a precisão de três técnicas de preenchimento do molde com gesso para obtenção de modelos de trabalho a partir de um modelo mestre simulando uma situação clínica de uma prótese fixa implanto-retida de três elementos. Materiais e métodos: Foram obtidos trinta modelos (n = 10) a partir do modelo mestre, por meio de três técnicas de preenchimento do molde com gesso. Assim, o Grupo 1 foi obtido pela técnica de preenchimento único (PU); o Grupo 2, pelo preenchimento do molde com gesso em duas porções (DP); o Grupo 3, utilizando-se a técnica do cilindro de latex (CL). Sobre a matriz metálica foi obtida uma infraestrutura fundida em titânio comer-cialmente puro simulando uma prótese fixa implanto-retida de três elementos, utilizada como referência para a avaliação de desajustes verticais em cada modelo. O desajuste vertical foi avaliado segundo a técnica do parafuso único. Para a análise dos resultados foi aplicada a análise de variância, seguida do teste de Tukey. Resultados: De acordo com os resultados obtidos, observou-se maior valor médio entre as amostras do grupo em que o molde foi preenchido com gesso pela técnica do preenchimento único (média = 0,14), ao passo que as amostras dos grupos 2 e 3 apresentaram os mesmos valores médios (média = 0,10). Porém, de acordo com o teste de Tukey, não houve diferença estatística entre os três diferentes grupos de tratamento. Conclusão: Assim, pode-se afirmar que as três técnicas foram eficientes, sendo, de acordo com a praticidade, a mais indicada a técnica de preenchimento único.

5.
Braz. j. oral sci ; 9(1): 48-53, Jan.-Mar. 2010. ilus
Article in English | LILACS, BBO | ID: lil-578047

ABSTRACT

Aim: This study used a photoelastic analysis to evaluate the passive fit of titanium cast laserwelding frameworks before and after spark erosion procedure. Methods: A stainless steel castwas used in order to reproduce a human mandible. Five Multi-Unit abutment analogs wereattached to this cast and 6 frameworks were produced in commercial pure titanium. The cast wasmolded and a photoelastic matrix was produced incorporating 5 dental implants with Multi-Unitabutments. All samples were subjected to a laser welding. The precision of adjustments within arange of 0.5 ìm was evaluated under microscope observation. The best fitted framework wasselected and subjected to a photoelastic analysis (Group I). The tightening of the screws was in 3predetermined sequences (1,2,3,4,5/ 5,4,3,2,1/ 3,2,4,1,5). Then the same framework wassubjected to a refinement by spark erosion technique (Group II) and evaluated by photoelasticanalysis. Results: The sequence (3,2,4,1,5) achieved better results in both groups. A largernumber of fringes were observed around the median implants in all sequences in both groups.Conclusions: The titanium cast laser welded frameworks processes associated with spark erosionprocedure improves significantly the marginal framework adaptation and is effective for its passive fit.


Subject(s)
Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Titanium , Biomechanical Phenomena , Dental Casting Technique , Materials Testing , Stress, Mechanical
6.
RFO UPF ; 14(1): 47-50, jan.-abr. 2009. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-516899

ABSTRACT

A indução de tensões ao implante e ao tecido ósseo peri-implantar pode ser responsável pela reabsorção tecidual e pela perda do implante. Próteses com o mínimo desajuste marginal são desejadas, acreditando-se na geração de menores valores de tensão às fixações .No entanto, não se tem certeza desta correlação, uma vez que a literatura não apresenta resultados confiáveis que venham a elucidar tal aspecto. Assim, o objetivo deste trabalho foi verificar se existe correlação entre os valores de desajuste marginal e de tensão gerados às fixações pelo parafusamento de infraestruturas implanto-retidas. Foram obtidas dez infraestruturas em titânio fundido, utilizando-se matriz metálica contendo dois implantes conectados a pilares cônicos para construções múltiplas. As infraestruturas foram aleatoriamente avaliadas quanto aos desajustes marginais mediante o teste do parafuso único e observação em microscópio ótico(120X). As tensões nas fixações foram avaliadas por extensometria. A média de desajuste marginal foi 118,07(58,61) μm e a média de tensão, 580,06 (253,93) gf.O teste de Pearson foi utilizado, mostrando não haver correlação entre desajuste marginal e tensão (-0,072),com p = 0,842. A presença e a intensidade do desajuste marginal, por si só, não são indicadores seguros no prognóstico da geração de tensões às fixações


Subject(s)
Dental Prosthesis , Dental Implants , Tensile Strength
7.
RPG rev. pos-grad ; 15(3): 186-190, jul. -set. 2008. tab, ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-543741

ABSTRACT

Tensões ao implante e ao tecido ósseo peri-implantar podem causar reabsorção e perda de componentes. A magnitude das tensões pode variar com o uso pilares intermediários entre a prótese e os implantes. Assim, o objetivo deste trabalho foi verificar as tensões induzidas aos implantes quando submetidos ao torqueamento de infraestruturas protéicas com e sem o uso de pilar intermediário. Vinte infraestruturas em titâneo (n=10) foram obtidas por fundição a partir de matriz metálica contendo dois implantes, simulando prótese fixa de três elementos. Dez peças foram confeccionadas utilizando copings calcináveis tipo UCLA diretamente sobre os implantes. Outras dez foram confeccionadas sobre pilares cônicos intermediários para construções múltiplas. As tensões foram aferidas após o torqueamento de cada estrutura mediante o uso de extensômetros calibrados. A média de tensão no grupo UCLA foi 665,35 (173,99) gf e no grupo minipilar cônico foi 580,06 (253,93) gf. O teste t de Student foi utilizado para a comparação intergrupos. Não houve diferença estatística para os valores de tensão entre os dois grupos (p > 0,3924). O uso do pilar intermediário em infraestruturas de três elementos em Ti c.p. fundido não reduziu as tensões induzidas aos implantes.


Subject(s)
Dental Prosthesis , Dental Implants , Prosthesis Failure , Bone Screws , Dental Stress Analysis , Denture, Partial, Fixed , Tensile Strength
8.
Odontol. clín.-cient ; 7(2): 165-169, abr.-jun. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-505865

ABSTRACT

O presente artigo descreve um método alternativo de moldagem de transferência na qual possibilita copiar os implantes bem como o contorno dos tecidos peri-implantares de forma simultânea. Para isso, utiliza-se resina composta fluída fotopolimerizável com o intuito de se reproduzir os tecidos gengivais no modelo funconal. Esta técnica tem como vantagem, a reprodução do perfil de emergência, fundamental na estética final da restauração.


The present article described an alternative impression technique for tranfer that is possible to simultaneous copy implants and gingival contours. For that, it used a flow composite resin, with the purpose to reestablish the gingival tissues to functional cast. The advantages to this technique is correctly replayed the emergency contour, considered very important in the final esthetic of the prosthetic restoration.


Subject(s)
Composite Resins , Dental Implants , Dental Impression Technique
9.
Ciênc. odontol. bras ; 11(2): 71-77, abr.-jun. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-524134

ABSTRACT

Esse trabalho avaliou o efeito de agentes de limpeza sobre as características superficiais de materiais resilientes. Foram utilizados os materiais Luci Sof (Dentsply), Molloplast-B (Dentax) e Sofreliner (Tokuyama), e os agentes de limpeza Hipoclorito de Sódio a 0,5% (Medicinallis - Farmácia de Manipulação) e Efferdent (Warner-Lamber Co). Foram confeccionados 20 corpos de prova de cada material. Os agentes de limpeza foram utilizados da seguinte maneira: 1) Hipocloritode sódio a 0,5% (HA) a 37 ± 1 ºC, durante 20 min; 2) Peróxido Alcalino (PA) a 37 ±1 ºC, durante 15 min. Após as imersões, os corpos de prova foram lavados e imersos em água destilada a 37 ±1 ºC pelo período restante das 24 h (8x ao dia, durante 90 dias). A rugosidade superficial foi avaliada em rugosímetro Surfcorder SE 1700 (Kosaka- Laboratory Ltda),após 0 (T1), 180 (T2), 360 (T3) e 720 (T4) ciclos de higienização. Os resultados foram submetidos à ANOVA e teste de Tukey (5%). Para a imersão em HA, Luci Sof apresentou redução significativa dos valores de rugosidade superficial em T2, T3 e T4; e o material Sofreliner, em todos os tempos. Para a imersão em PA, Luci Sof apresentou redução significativa dos valores em T2, T3 e T4; Molloplast-B, redução significativa em T3; Sofreliner, aumento significativo em T4. Concluiu-se que a imersão em agentes químicos de limpeza, em geral, reduz a rugosidade superficial de reembasadores resilientes.Molloplast-B apresentou comportamento linear durante o estudo. Sofreliner, imerso em Hipoclorito, apresentou valores de rugosidade inferiores ao considerado mínimo para retenção bacteriana.


Subject(s)
Disinfection , Denture, Complete , Denture Liners
10.
Ciênc. odontol. bras ; 11(01): 27-34, jan.-mar. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-502327

ABSTRACT

O assentamento passivo de próteses fixas implanto-suportadas pode ser obtido por procedimentos laboratoriais. O objetivo deste estudo foi avaliar comparativamente a formação de tensões induzidas por infra-estruturas implanto-suportadas obtidaspor duas técnicas através da análise fotoelástica. Dois grupos de infra-estrututas em titânio comercialmente puro foram obtidos sobre uma matriz metálica: I) três infra-estruturas confeccionadas pela técnica da soldagem de borda de cilindrose II) três infra-estruturas fundidas em monobloco e submetidas ao sistema de retificação de cilindros. Após análise emmicroscopia óptica, apenas a estrutura mais bem adaptada de cada grupo foi submetida à análise de tensões, em três seqüências de aperto dos parafusos protéticos. Após, a estrutura do grupo II sofreu secção e soldagem e foi novamente submetida à análise fotoelástica. Os resultados mostraram maior magnitude de tensões com a seqüência de aperto de parafusos daesquerda para direita e vice-versa, para ambos os grupos. A estrutura do grupo I induziu menor concentração de tensões,mesmo tendo apresentado maiores valores de desadaptação (165μm) comparada ao grupo II antes (54μm) e após secção e soldagem a laser (117μm). A técnica da soldagem de borda a laser, associada à seqüência de aperto do parafuso protéticodo centro para as extremidades, obteve melhores resultados formação de tensões para este tipo de reabilitação.


The passive fit of implanted-supported fixed rehabilitation may be achieved with laboratorial procedures. The aim of this study was evaluate the stress formation induced by two techniques indicated to obtain implant-supported fixed prostheses with satisfactory passive fit by means of photoelastic analysis. Two titanium casts groups were fabricated in a metallic master cast: Group I- three frameworks fabricated by laser welded cylinder technique and Group II- three frameworks cast in one-piece and submitted to cylinder refinement system. After optical microscopy valuation, only the better-fit frameworkof both groups was submitted to the photoelastic analysis, testing three screw tightening sequences. Subsequent to the first analysis the selective framework of Group II was sectioned and laser welded to be submitted to a new evaluation. Results showed superior stress magnitude formation in screw tightening sequences from left to right and vice-versa of both groups,while medial to distal screw tightening sequence presented better results to Branemark protocolo rehabilitation. The group I framework illustrated better results, even though had showed superior values of misfit (165μm) compared to group II before (54μm) and after section and laser welded (117μm). Laser welded cylinder technique achieved better results to thistype of rehabilitation mainly allied to the medial to distal prosthetic screw tightening sequence.


Subject(s)
Dental Prosthesis, Implant-Supported , Dental Soldering , Biomechanical Phenomena
11.
RPG rev. pos-grad ; 14(4): 321-326, out.-dez. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-529483

ABSTRACT

Esse trabalho avaliou os efeitos da pós-polimerização sobre as propriedades de resistência à tração de uma resina acrílica para base de prótese (QC-20) unida a reembasadores rígidos (New Truliner e Kooliner). Os materias utilizados foram proporcionados e manipulados, segundo as recomendações dos fabricantes. Foram confeccionados 40 amostras, separadas em quatro grupos (n = 10): G1: amostras reembasadas com Kooliner, sem o efeito da pós-polimerização (PP); G2: amostras reembasadas com New Truliner, sem PP; G3: amostras reembasadas com Kooliner, com PP, utilizando microondas com potência de 650W/5 min e G4: amostras reembasadas com New Truliner, com PP. As amostras foram confeccionadas utilizando matrizes metálicas incluídas em mufla, cujo molde impresso no silicone de condensação foi preenchido com resina acrílica. Após polimerizadas, as amostras em resina (40x10x10 mm), foram unidas duas a duas em seu eixo longitudinal pelo reembasador rígido (3 mm), e armazenadas em água destilada à + - 37°C durante uma semana. O ensaio de resistência à tração foi realizado em máquina universal EMIC DL-500 MF com velocidade de 5 mm/min. Os resultados obtidos foram submetidos a ANOVA e teste de Tukey (5%). A pós-polimerização não influenciou significativamente a resistência à tração de nenhum dos dois materiais ensaiados. O material Krooline apresentou valores significativamente maiores de resistência à tração tanto com PP quanto sem, quando comparado ao New Truliner.


Subject(s)
Acrylic Resins , Denture Liners , Tensile Strength , Analysis of Variance , Denture Bases , Dental Materials/analysis
12.
Braz. j. oral sci ; 6(20): 1269-1273, Jan-Mar. 2007. ilus, graf
Article in English | LILACS, BBO | ID: biblio-850523

ABSTRACT

This study verified through electromyography the masticatory muscle behavior resulting of the balancing ramps technique to obtain balance in double complete dentures. Eleven totally edentulous patients that used their complete dentures for 5 years at least, had new other ones made and balanced by the balancing ramp technique. The electromyographyc (EMG) activity pattern was registered in anterior temporal (T) and masseter (M) muscles in the rest position (R) and in the maximal voluntary contraction in the intercuspal position (MVCIP), using Myosystem I« (Prosecon Ltda., Uberlândia, MG, Brazil), in four experimental moments: T0 û before the prostheses installation; T1 û 1 month after installation; T2 û 2 months after installation; T3 û 3 months after installation. Results showed a symmetry reduction between T muscles and a little increasing between M muscles in the R position. In the MVCIP position, it there was a reduction for both T and M muscles. The F test showed no statistical significant differences (p<0.05). Authors concluded that the employed technique promote no balance of the masticatory muscles in the tested experimental moments.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Dental Occlusion, Balanced , Denture, Complete , Electromyography , Masticatory Muscles , Dental Occlusion
13.
RPG rev. pos-grad ; 14(1): 31-38, jan.-mar. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-529443

ABSTRACT

O presente estudo avaliou a distribuição de tensões, por meio da análise fotoelástica de infra-estruturas de próteses fixas implanto-suportadas, confeccionadas pelas técnicas do cilindro cimentado e soldado a laser. As estruturas foram obtidas a partir de uma matriz metálica com formas e dimensões similares a um arco mandibular. Foram confeccionadas seis estruturas metálicas fundidas em titâneo comercialmente puro (Rematitan, Dentaurum®, Pforzheim, Alemanha), dividas em dois grupos: Grupo I - cilindros cimentados com cimento resinoso (Panavia F® Kuraray Co., Japão) e Grupo II - cilindros soldados a laser. Foram feitas mensurações com auxílio de um microscópio mensurador, com precisão de 0,0005 mm (STM Digital, Olympus, Japão), por meio do teste do parafuso único. Foi, então escolhida a estrutura mais bem-adaptada para cada um dos grupos, para a realização da análise fotoelástica, que foi realizada sobre um modelo confecccionado em resina fotoelática (Araldite® GY279BR Huntsman - Araltec Produtos Químicos Ltda., Guarulhos/SP), variando três sequências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). Os resultados indicaram que, para os grupos analisados, maior quantidade de tensões foi observada na sequência de aperto 1/2/3/4/5. O grupo dos cilindros cimentados mostrou os melhores resultados, com menores valores de desadaptação (43,95 e 22,07 µm) quando comparado ao grupo dos cilindros soldados a laser (198,8 µm e 60,17 µm). A sequência de aperto 3/2/4/1/5 mostrou menor quantidade de tensões para o grupo dos cilindros cimentados. A sequência 5/4/3/2/1 apresentou melhores resultados para o grupo dos cilindros soldados a laser. A técnica dos cilindros cimentados apresentou melhores resultados, associada à sequência 3/2/4/1/5.


Subject(s)
Dental Prosthesis, Implant-Supported , Dental Soldering , Lasers , Dental Implantation, Endosseous , Dental Pins , Titanium
14.
Rev. odontol. UNESP ; 36(1): 35-40, jan.-mar. 2007. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-529250

ABSTRACT

Este trabalho teve como objetivo avaliar o efeito da escovação mecânica sobre a rugosidade superficial de três materiais reembasadores resilientes considerados definitivos: dois à base de silicone, sendo um autopolimerizável (Sofreliner MS) e outro termopolimerizável (Molloplast-B), além de um reembasador resiliente de resina acrílica autopolimerizável (Dentuflex). Para a confecção das amostras, foram utilizadas matrizes de silicone polimerizado por reação de condensação incluídas em muflas vindo a obter-se um molde impresso no gesso, posteriormente preenchido com os materiais. Foram confeccionadas ao todo 30 amostras (10 de cada material), submetidas à leitura de rugosidade superficial num rugosímetro (SURFCORDER SE 1700 Kosaka Laboratory), tendo sido os valores obtidos em Ra. Em seguida, as amostras foram submetidas ao ensaio de escovação mecânica em uma máquina MSEt. O ensaio de escovação foi executado sob carga estática de 200 g, com movimentos lineares, totalizando 30.000 ciclos, e liberação de solução de dentifrício contendo água a cada um minuto sobre as amostras. Após os ensaios, foram executadas novas leituras de rugosidade superficial. Os valores obtidos foram submetidos à análise de variância (ANOVA) com medidas repetidas seguida do teste de Tukey em nível de 5% de significância. Inicialmente o material Dentuflex apresentou maior índice de rugosidade, seguido do Molloplast – B e do Sofreliner MS. Após a escovação, o material Dentuflex apresentou diminuição nos valores de rugosidade, o Sofreliner MS aumento (ambos estatisticamente significantes) e o Molloplast-B manutenção dos valores.


The aim of this study was to evaluate the effect of mechanical brushing on the roughness of three resilient definitive lining materials: 1) auto (Sofreliner MS); 2) heat-polymerized (Molloplast-B) silicone based materials; and 3) auto-polymerized plasticized acrylic resin (Dentuflex). To prepare the samples, silicone rubber patterns were made and placed in a flask to obtain a cast pressed mold, and then filled with resilient lining materials. Thirty samples (10 for each denture liner) were prepared and submitted to surface roughness readings using a profilometer (SURFCORDER SE 1700 – Kosaka Laboratory). The roughness values were obtained in Ra (ìm). After roughness measurements, the samples were submitted to a mechanical brushing simulation in an MSEt. The samples were submitted to 30.000 strokes with linear brushing movements, under a 200 g static load pressure. Toothpaste solution was injected every one-minute break. New readings of roughness were done, and the values were submitted to repeat measures analysis of variance (ANOVA) followed by Tukey’s test, with 5% of significance. Dentuflex showed the highest initial roughness values, followed by Molloplast-B and Sofreliner MS. After mechanical brushing, Dentuflex showed a decrease in the mean roughness value whereas Sofreliner MS showed an increase of values and Molloplast-B remained unaffected.


Subject(s)
Denture, Complete
15.
Rev. cir. traumatol. buco-maxilo-fac ; 6(4): 49-56, out.-dez. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-461788

ABSTRACT

O restabelecimento do espaço interarcos pode ser obtido através da osteotomia segmentar posterior da maxila. Esta consiste na mobilização e movimentação de um segmento posterior da maxila com o objetivo de restabelecer o espaço protético adequado entre a maxila e a mandíbula, além de corrigir mordidas cruzadas, mordidas abertas posteriores, proporcionando o reposicionamento superior, inferior, distal e mesial do segmento em um único tempo operatório. As indicações, técnicas e complicações da osteotomia segmentar posterior da maxila serão discutidas por meio de uma revisão de literatura e relato de um caso, na qual é enfatizada a necessidade do envolvimento de duas especialidades odontológicas.


Subject(s)
Malocclusion , Osteotomy, Le Fort
16.
J. appl. oral sci ; 14(4): 286-290, July-Aug. 2006. ilus
Article in English | LILACS, BBO | ID: lil-447836

ABSTRACT

PURPOSE: Difficulty in cleaning resilient denture liners remains a material disadvantage. The purpose of the present study was to evaluate the effect of denture cleansers on hardness of resilient liner materials. MATERIALS AND METHODS: Three resilient liners, Luci Sof® (Dentsply), Molloplast-B® (Dentax), and Sofreliner® (Tokuyama), and two denture cleansers, Efferdent® (Warner-Lamber), and 0.5 percent alkaline hypochlorite preparation were used. Twenty specimens of each material were prepared, measuring 25X15X3mm. Two denture cleansing approaches were used: 1) alkaline hypochlorite, for 20 minutes; 2) alkaline peroxide, for 30 minutes. This procedure was repeated 8 times a day, during 90 days. The specimens were evaluated before and after 360 and 720 cycles, to simulate 1 and 2 years of clinical cleaning procedures, respectively. The Shore A hardness was evaluated in a durometer (Teclock GS-709A), with a penetrating load of 10N for 1 second. Any macroscopic changes, such as loss of color or alteration in surface texture were recorded by one observer. All numeric data were subject to ANOVA with repeated measures followed by Tukey's test (alpha= 0.05). RESULTS: All materials were significantly different, independently to time and treatment. Initially, Luci Sof® and Sofreliner® immersed in either hypochlorite or peroxide increased the hardness mean values significantly. These hardness mean values decreased significantly after 720 cycles. Molloplast-B® showed no significant difference after the treatments, in any time. CONCLUSIONS: Denture cleansers had no effect on hardness of the resilient denture liners evaluated after 2 years of in vivo simulated conditions of hygiene. Sofreliner® was the smoothest material before and after all treatments.


PROPOSIÇÃO: A maior desvantagem dos materiais reembasadores resilientes é a dificuldade em mantê-los limpos. Esse trabalho avaliou o efeito de agentes de limpeza sobre a dureza de reembasadores resilientes. MATERIAL E MÉTODOS: Foram utilizados os materiais Luci Sof® (Dentsply), Molloplast-B® (Dentax) e Sofreliner® (Tokuyama), e os agentes de limpeza Hipoclorito de Sódio a 0,5 por cento (Medicinallis-Farmácia de Manipulação) e Efferdent® (Warner-Lamber). Foram confeccionadas 20 amostras de cada material, com dimensões de 25X14X3mm. Foram realizados 2 tratamentos: 1) Hipoclorito de Sódio a 0,5 por cento a 37 + 1°C, durante 20 minutos; 2) Peróxido Alcalino, a 37 + 1°C, durante 30 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 ± 1°C, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias. A dureza foi avaliada antes e após 360 e 720 ciclos, correspondente a 1 e 2 anos de uso clínico, respectivamente. O ensaio de dureza Shore A foi realizado em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10 N por 1 segundo. Alterações macroscópicas, como perda de cor e alteração da superfície, foram avaliadas por um observador. Os resultados obtidos foram submetidos à ANOVA com medidas repetidas e ao Teste de Tukey (5 por cento). RESULTADOS: Os materiais apresentaram diferença significante nos valores médios de dureza, independente do tratamento e do tempo. Luci Sof® e Sofreliner® aumentaram os valores médios de dureza inicialmente, os quais diminuíram após 720 ciclos significativamente, para ambos os tratamentos. Molloplast-B® não apresentou diferença significante nos diferentes tempos e tratamentos. CONCLUSÕES: Os tratamentos em agentes de limpeza não alteraram os valores de dureza dos reembasadores resilientes após 2 anos de simulação clínica. Sofreliner® apresentou os menores valores de dureza, em todos os tempos e tratamentos, apresentando-se como...


Subject(s)
Denture Liners , Denture, Complete , Detergents/adverse effects , Hardness Tests , Silicones
17.
J. appl. oral sci ; 14(4): 286-290, July-Aug. 2006. ilus
Article in English | LILACS, BBO | ID: biblio-873282

ABSTRACT

PROPOSIÇÃO: A maior desvantagem dos materiais reembasadores resilientes é a dificuldade em mantê-los limpos. Esse trabalho avaliou o efeito de agentes de limpeza sobre a dureza de reembasadores resilientes. MATERIAL E MÉTODOS: Foram utilizados os materiais Luci Sof« (Dentsply), Molloplast-B« (Dentax) e Sofreliner« (Tokuyama), e os agentes de limpeza Hipoclorito de Sódio a 0,5 por cento (Medicinallis-Farmácia de Manipulação) e Efferdent« (Warner-Lamber). Foram confeccionadas 20 amostras de cada material, com dimensões de 25X14X3mm. Foram realizados 2 tratamentos: 1) Hipoclorito de Sódio a 0,5 por cento a 37 + 1ºC, durante 20 minutos; 2) Peróxido Alcalino, a 37 + 1ºC, durante 30 minutos. Após as imersões, as amostras foram lavadas e imersas em água destilada, a 37 ± 1ºC, pelo período restante das 24 h. Esse processo foi repetido 8 vezes por dia, durante 90 dias. A dureza foi avaliada antes e após 360 e 720 ciclos, correspondente a 1 e 2 anos de uso clínico, respectivamente. O ensaio de dureza Shore A foi realizado em durômetro modelo GS-709 (Teclock-Japão), com aplicação de carga de 10 N por 1 segundo. Alterações macroscópicas, como perda de cor e alteração da superfície, foram avaliadas por um observador. Os resultados obtidos foram submetidos à ANOVA com medidas repetidas e ao Teste de Tukey (5 por cento). RESULTADOS: Os materiais apresentaram diferença significante nos valores médios de dureza, independente do tratamento e do tempo. Luci Sof« e Sofreliner« aumentaram os valores médios de dureza inicialmente, os quais diminuíram após 720 ciclos significativamente, para ambos os tratamentos. Molloplast-B« não apresentou diferença significante nos diferentes tempos e tratamentos. CONCLUSÕES: Os tratamentos em agentes de limpeza não alteraram os valores de dureza dos reembasadores resilientes após 2 anos de simulação clínica. Sofreliner« apresentou os menores valores de dureza, em todos os tempos e tratamentos, apresentando-se como o material mais macio


Subject(s)
Denture Liners , Denture, Complete , Detergents/adverse effects , Hardness Tests , Silicones
18.
Rev. odonto ciênc ; 21(52): 172-178, abr.-jun. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-457148

ABSTRACT

O objetivo deste estudo foi avaliar, através da eletromiografia, o comportamento da atividade muscular resultante do uso da técnica Convencional para obtenção de equilíbrio em prótese total dupla. Doze pacientes totalmente edêntulos, livres de sinais e sintomas de disfunção temporomandibular com no mínimo cinco anos de uso de próteses totais, foram selecionados. Os pacientes tiveram suas próteses substituídas por novas próteses e o equilíbrio articular obtido através do estabelecimento de contatos interferentes entre dentes artificiais. O padrão da atividade eletromiográfica (EMG) foi mensurado com o eletromiógrafo Myosystem Iâ (Prosecon Ltda) nos músculos temporais (porção anterior) e masseteres nas posições de repouso (R) e na contração isométrica em máxima intercuspidação (CIMI), em quatro tempos: TO - instalação; T1 - 1° mês; T2 - 2° mês; T3 - 3° mês de uso das próteses. O sinal eletromiográfico foi condicionado por um filtro digital passa faixa e analisado em relação a sua amplitude através do RMS (Root Mean Square). Observou-se pequenas alterações nos valores da atividade EMG dos músculos temporais e masseteres na posição de R. Na posição de CIMI os músculos temporais apresentaram valores finais menores que os iniciais, e situação inversa foi observada para os masseteres, com valores finais maiores que os iniciais. A análise dos dados através do teste de Friedman não mostrou diferenças estatísticamente significantes (p < 0.05) entre os tempos avaliados. Conclui-se que a técnica Convencional, no período avaliado, não proporcionou equilíbrio dos músculos mastigatórios estudados.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Masticatory Muscles , Dental Occlusion, Balanced , Denture, Complete, Lower , Denture, Complete, Upper , Electromyography
19.
RFO UPF ; 11(2): 36-40, 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-457380

ABSTRACT

Em coroas totais metálicas é requerido o máximo de ajuste de margens ao elemento dental para que haja longevidade das restaurações. O objetivo deste estudo foi avaliar a influência de padrões de fundição confeccionados em cera, resina acrílica Duralay e resina acrílica Pattern no desajuste marginal de coroas fundidas em titânio comercialmente puro (Ti c.p). Com o auxílio de um torno mecânico, dez dentes bovinos foram preparados para receber coroas metálicas. Modelos em gesso especial tipo V foram confeccionados a partir dos dentes bovinos, por moldagem com silicone de adição. Trinta coroas de titânio foram fundidas em três grupos (n = 10), divididos pelo material usado na elaboração dos padrões de fundição: cera, resina acrílica Duralay e resina acrílica Pattern. Os valores de desajustes marginais foram registrados em quatro pontos de medida de cada coroa fundida por um microscópio mensurador (120X). pela análise de variância e tete de Tukey (p ≤ 0,05) não foram constatadas diferenças estatisticamente significativas entre os valores médios de desajuste marginal do grupo padrão em cera (151,20 ± 47,40 µm) e os demais grupos: padrão em resina Duralay (153,60 ± 37,10 µm) e padrão em resina Pattern (165 ± 32,50 µm). Conclui-se que o material utilizado na confecção de padrões de fundição não interfere na adaptação marginal de coroas fundidas em titânio.


Subject(s)
Animals , Male , Female , Cattle , Acrylic Resins , Crowns , Dental Marginal Adaptation , Dental Prosthesis , Titanium , Waxes , Casts, Surgical , Silicones
20.
Braz. dent. j ; 17(2): 126-129, 2006. tab
Article in English | LILACS | ID: lil-433499

ABSTRACT

O objetivo deste estudo foi avaliar o efeito de tratamentos térmicos na dureza Vickers do titânio comercialmente puro e da liga Ti-6Al-4V. Corpos-de-prova cilíndricos com 6 mm de diâmetro foram fundidos no sistema Rematitan. Os corpos-de-prova de titânio comercialmente puro e da liga Ti-6Al-4V foram divididos aleatoriamente em 3 grupos (n=10): controle (sem tratamento térmico); tratamento 1 (T1): aquecido a 750ºC por 2 h; tratamento 2 (T2): aquecido a 955ºC por 1 h e envelhecido a 620ºC por 2 h. Após os tratamentos térmicos, os corpos-de-prova foram incluídos em resina acrílica, a superfície foi regularizada e polida, e a dureza foi mensurada. As médias de dureza Vickers (VHN) e os desvios padrão foram analisados estatisticamente usando o teste de Kruskal-Wallis com nível de significância a 5%. Para o titânio comercialmente puro, a média de dureza do grupo T2 (259,90 VHN) foi significativamente maior que os outros grupos (controle-200,26 VHN e T1-202,23 VHN) (p<0,05), que apresentaram valores médios similares (p>0,05). Para a liga Ti-6Al-4V, diferenças estatisticamente significantes foram observadas entre os três grupos: T2 (369,08 VHN), T1 (351,94 VHN) e controle (340,51 VHN) (p<0,05). Os resultados demonstraram diferente comportamento de dureza do titânio comercialmente puro e da liga Ti-6Al-4V quando diferentes tratamentos foram usados. Para o titânio comercialmente puro, a média de VHN grupo T2 foi consideravelmente maior que as médias dos grupos controle e T1, os quais demonstraram médias similares entre si. Para a liga Ti-6Al-4V, entretanto, a média de VHN registrada para cada grupo pode ser apresentada da seguinte maneira: T2>T1>controle.


Subject(s)
Hot Temperature , Titanium/chemistry , Hardness , Random Allocation
SELECTION OF CITATIONS
SEARCH DETAIL